Provide customized design one-stop service

PEM Electrolyzer Active Area: How to Match the CCM, PTL and Gasket

Nov. 21, 2026

Share:

A 25 cm² catalyst-coated membrane (CCM) and a 25 cm² porous transport layer (PTL) can have different shapes, edge details and alignment requirements. Before requesting samples for a PEM water electrolyzer, compare the coating boundary, PTL footprint and gasket opening on the same cell drawing.

What Does Active Area Mean in a PEM Electrolyzer?

Geometric active area is the reference area used to report the cell's current density. Ask the supplier or test lab how that area is defined for the specific hardware. The coated area is the region covered by catalyst on a membrane face. The membrane outline, PTL footprint and gasket opening are separate drawing dimensions. Each can have a different shape or size.

Plan-view schematic comparing the membrane outline, gasket opening, PTL footprint and CCM coated area

Figure 1. Illustrative overlay of component boundaries. Their relative positions and dimensions depend on the cell design.

How Do You Check CCM, PTL and Gasket Alignment?

Use one drawing origin and a consistent view for each side. Overlay the coating boundary, porous component outline and gasket opening. Check where each edge falls relative to the recess and sealing land. Confirm the anode and cathode orientations independently, because the two sides can use different shapes or materials.

Review the plan view together with a cross section. The plan view shows whether edges and cutouts register. The cross section shows how thickness, recess depth and the specified compression affect contact and sealing. See the CCM selection guide and titanium PTL selection guide for the material and interface details.

Can Two 25 cm² Parts Fit the Same Cell?

Area alone cannot establish fit. A 50 × 50 mm square and a 40 × 62.5 mm rectangle each cover 2,500 mm² (25 cm²). Their edges land in different positions even when their centers align. Check length, width, corners and tolerances before treating samples as interchangeable.

A 50 by 50 mm square and a 62.5 by 40 mm rectangle, each with an area of 25 square centimeters

Figure 2. Equal geometric area with two different footprints. Example dimensions are illustrative.

Which Dimensions Should an OEM Buyer Compare?

ItemDrawing detailsQuestion to confirm
CCM coatingCoated length and width on each side, corner shape and coating locationDoes the coating align with the intended working region on both faces?
Membrane outlineOverall dimensions, edge margin, cutouts and orientationDoes the membrane fit the drawing and reach the specified sealing land?
PTL footprintLength, width, corner radius, orientation and thickness toleranceDoes the PTL fit the recess and meet the specified contact and compression conditions?
Gasket openingInner and outer outline, sealing land and gasket thicknessDoes the opening clear the specified parts and leave the designed sealing surface?
Alignment and area basisCommon datum, registration tolerance and area used for current densityAre the drawings referenced to the same origin, and is the test area stated explicitly?

When comparing polarization curves, ask how the geometric area was defined and how the cell was assembled and tested. Record the test hardware and conditions alongside each curve. See the published PEM water electrolysis reference protocol for an example of documented hardware and test methods.

What Should You Include in a Sample Request?

  • Drawing revision, units, anode and cathode orientation, and a shared alignment datum.

  • Nominal cell active area and how the drawing or test report defines it.

  • CCM outline, separate coating boundaries, PTL dimensions and gasket opening.

  • Relevant tolerances, recess depth and your assembly's specified compression conditions.

  • Which components you need, quantity and the documentation needed for sample approval.

Frequently Asked Questions

Is the CCM coated area always the cell active area?

They may coincide in a given design. Ask which boundary the drawing uses and which area the test report uses to calculate current density.

Can I approve a sample using only the outer dimensions?

Request the coating location, cutouts, corner details and alignment tolerances as well. For fit approval, compare the correct revision of the cell drawing.

Should the gasket opening and PTL have identical dimensions?

The required clearance and overlap depend on the recess and sealing design. Confirm both outlines and the specified assembly conditions with the cell designer.

Discuss a CCM sample for your PEM cell

Share your drawing, area definition and sample requirements so Gitan can review the dimensions with you. Contact Gitan about your CCM project.

Previous post

None

Next post

How to Select a CCM for a PEM Water Electrolyzer

Need Custom Design and Development for CCM And PEM Electrolyzers?

We strongly support customer personalisation and customisation, providing the most suitable solutions based on different customer needs. If you have any customisation requirements, please contact us and we will provide you with the most professional advice and products.

View More

Related Products

We R&D, design, manufacturing and sales of PEM membrane electrodes, hydrogen and oxygen electrolytic cells and other ancillary products.

PEM Hydrogen Generator A400D‑2200 400 mL/min Water Electrolysis Unit

The 400ml 200ml/layer series Single-Output Hydrogen-Oxygen Electrolyzer is composed of a stacked combination of dual-layer 200ml PEM proton exchange membrane.

300ml/min Pure Titanium PEM Electrolyzer Q300C-2150 with DuPont Proton Exchange Membrane for Gas Calibration & Environmental Monitoring

The 300ml 150ml/layer series Hydrogen-Oxygen Electrolyzer Module uses a catalyst-coated PEM for stable performance and long lifespan (up to 8000 hours). With dual hydrogen and single oxygen output, this module features a compact design, low working voltage, and reliable operation, making it ideal for hydrogen-oxygen separation.

Durable PEM Electrolysis Chamber for Long-Life Hydrogen Production

The 600ml 150ml/layer series Hydrogen-Oxygen Electrolyzer Module is equipped with dual hydrogen outputs and single oxygen output for efficient hydrogen-oxygen separation. Featuring catalyst-coated PEM, low working voltage, and a long operational lifespan of 8000 hours, this module provides stable and reliable performance

Compact PEM Electrolyzers for On-Demand Hydrogen Generation at Home

The 1500ml 250ml/layer series Dual-Output Hydrogen-Oxygen Electrolyzer is composed of six layers of 250ml PEM proton exchange membranes stacked together.

900ml/min Hydrogen Storage with PEM Electrolyzers - Sustainable Solutions for Green Energy A900A-6150

The 900ml 150ml/layer series Dual-Output Hydrogen-Oxygen Electrolyzer is composed of six layers of 150ml PEM proton exchange membranes stacked together.

11-Plate Electrolytic Alkaline Water Ionizer J002-11P for Home & Office Dispensers

The J002-11P Electrolyzer is designed for high-efficiency hydrogen production with an 11-layer microfiltration membrane, platinum coating for extended lifespan, and dual-sided coating for superior scale removal. Its compact structure ensures stable and reliable performance, making it ideal for sustainable energy applications.

600ml/min Hydrogen Electrolyzers for Research & Development - PEM Solutions for Scientific Projects Q600A-2300

The 600ml 300ml/layer series Dual-Output Hydrogen-Oxygen Electrolyzer is composed of two layers of 300ml PEM proton exchange membranes stacked together.

2500ml/min Pure Titanium PEM Electrolyzer A2500A-10250 with DuPont Proton Exchange Membrane for Renewable Hydrogen Production & Storage

The 2500ml 250ml/layer series Dual-Output Hydrogen-Oxygen Electrolyzer is composed of ten layers of 250ml PEM proton exchange membranes stacked together.