Provide customized design one-stop service
Introduction
The Gitan PEM Hydrogen and Oxygen Generator uses proton exchange membrane water electrolysis technology to generate hydrogen and oxygen through separate gas outlets.
The specified gas outputs are 1000mL/min hydrogen and 500mL/min oxygen. Separate connections allow the two gas streams to be routed individually according to the equipment instructions and application requirements.
The unit features a 3L water tank. Use purified or distilled water with TDS ≤ 5 ppm; do not use tap water or mineral water.
The specified DC electrical rating is 15V, 26A. Contact Gitan to confirm the complete power supply configuration, gas pressure, purity specifications, operating conditions and connection requirements before ordering.
Share:
Product Description
The Gitan PEM hydrogen and oxygen generator is a water electrolysis system with separate hydrogen and oxygen outlets. Its rated outputs are 1000mL/min for hydrogen and 500mL/min for oxygen.
The system uses a proton exchange membrane and electrode assembly to split water into hydrogen and oxygen. Hydrogen is generated at the cathode, while oxygen is generated at the anode. The gases are collected through separate outlet paths.
The specified hydrogen output is 1000mL/min, and the specified oxygen output is 500mL/min. The supplied illustration identifies the left connection as the hydrogen outlet and the right connection as the oxygen outlet when viewed from the front.
Always follow the outlet labels on the supplied equipment. Confirm connection dimensions, permitted backpressure and gas-handling requirements before connecting downstream equipment.
The machine has a specified 3L water tank. Use purified or distilled water with TDS ≤ 5 ppm. Tap water and mineral water are not suitable for the stated configuration.
Follow the operating instructions for filling level, water replacement and maintenance. Tank capacity alone does not establish continuous operating time.
The supplied DC electrical rating is 15V, 26A. Confirm the approved power supply, complete machine input requirements and whether this rating applies to the electrolysis assembly or the complete unit.
The illustrated enclosure includes a front control panel, side handles and caster wheels. Confirm the final supplied configuration, dimensions, weight, accessories and control functions before ordering.
For technical specifications, performance test conditions and purchasing details, contact Gitan.
Technical Specifications
| Parameter | Specification |
| Product Type | PEM Hydrogen and Oxygen Generator |
| Technology | Proton Exchange Membrane (PEM) Water Electrolysis |
| Rated Hydrogen Output | 1000mL/min |
| Rated Oxygen Output | 500mL/min |
| Gas Outlet Configuration | Separate Hydrogen and Oxygen Outlets |
| Outlet Arrangement | Left: Hydrogen; Right: Oxygen, as Illustrated from the Front. Follow Equipment Labels. |
| Specified DC Voltage | 15V DC |
| Specified DC Current | 26A |
| Water Tank Capacity | 3L |
| Required Water | Purified or Distilled Water |
| Water TDS Requirement | ≤ 5 ppm |
| Unsuitable Source Water | Tap Water / Mineral Water |
| Brand | Gitan |
Confirm gas flow reference conditions, purity, outlet pressure, continuous operating limits and the complete power supply configuration before ordering. The specified DC rating does not establish the complete machine's AC input power.
Product Advantages
Product Advantages
The Gitan PEM Hydrogen and Oxygen Generator uses proton exchange membrane water electrolysis technology to generate hydrogen and oxygen through separate outlets. Its specified outputs are 1000mL/min hydrogen and 500mL/min oxygen.
Hydrogen Output: 1000mL/min through the hydrogen outlet.
Oxygen Output: 500mL/min through the oxygen outlet.
Electrolysis Technology: Proton exchange membrane (PEM).
Specified DC Rating: 15V, 26A.
Water Tank Capacity: 3L.
Required Water: Purified or distilled water with TDS ≤ 5 ppm.
The generator uses a proton exchange membrane and electrode assembly to split water into hydrogen and oxygen. Hydrogen is generated at the cathode, while oxygen is generated at the anode.
The illustrated cell structure includes catalyst layers, diffusion layers and bipolar plates with flow channels. Separate gas paths collect the generated hydrogen and oxygen for delivery through their respective outlets.
The specified output rates are 1000mL/min for hydrogen and 500mL/min for oxygen. Confirm the flow reference conditions, measurement method and gas purity specifications when comparing equipment.

The machine provides independent hydrogen and oxygen outlet connections, allowing the two gas streams to be routed separately according to the equipment instructions.
Hydrogen Outlet: Rated output of 1000mL/min.
Oxygen Outlet: Rated output of 500mL/min.
Viewed from the front as illustrated, the hydrogen outlet is on the left and the oxygen outlet is on the right. Always follow the identification labels on the supplied equipment.
Confirm connection dimensions, compatible tubing, outlet pressure and permitted backpressure before connecting downstream equipment.

The generator features a 3L water tank. Use purified or distilled water with TDS ≤ 5 ppm to meet the stated water-quality requirement.
Do not use tap water or mineral water. Follow the operating instructions for filling level, water replacement and routine maintenance.
Water tank capacity describes storage volume and does not establish continuous operating time. Confirm the permitted operating schedule, refill procedure and maintenance intervals for the selected configuration.

The specified DC electrical rating is 15V, 26A. Confirm the approved power supply and whether this rating applies to the electrolysis assembly or the complete machine.
The complete machine's AC input voltage, frequency and power consumption must be confirmed separately. Follow the supplied electrical and installation instructions.
The illustrated enclosure includes a front control panel, side handles and caster wheels. Confirm the dimensions, weight, control functions and accessories included with the supplied unit.
Plan the installation around the required ventilation, service clearance, electrical supply and gas connections. Keep the equipment away from ignition sources and follow the operating instructions for gas handling.
Buyers can contact Gitan to discuss the assembly process, inspection criteria and performance testing for the selected configuration. Request supporting documentation for rated gas flow, gas purity, outlet pressure and electrical specifications.
For purchasing acceptance, agree on the test conditions, required documents and inspection requirements before placing an order.

Assembly and testing illustration. Contact Gitan for actual production information and applicable inspection documentation.
Equipment distributors, system integrators and project buyers can evaluate this generator against their hydrogen and oxygen supply requirements. Suitability depends on the required flow, purity, pressure, operating schedule and connection arrangement.
Provide Gitan with the intended application and downstream equipment requirements so the supplied configuration can be assessed before ordering.
Distributors, importers and brand owners can enquire about available customization, packaging, minimum order quantities, samples and lead times.
Please provide your destination market, required quantity, electrical requirements and documentation needs when requesting a quotation.
The specified hydrogen output is 1000mL/min. Confirm the flow reference conditions and measurement method when comparing performance specifications.
The specified oxygen output is 500mL/min through a separate oxygen outlet.
Yes. This configuration has separate hydrogen and oxygen outlets. Follow the labels on the supplied equipment when connecting gas lines.
Use purified or distilled water with TDS ≤ 5 ppm. Do not use tap water or mineral water.
The specified water tank capacity is 3L. Follow the instructions for filling limits and refilling.
It is the specified DC electrical rating. Confirm which assembly it applies to and obtain the complete machine's electrical input requirements before arranging a power supply.
Request verified gas purity specifications, pressure limits and associated test conditions from Gitan. These values cannot be determined from the flow rates alone.
Confirm gas flow reference conditions, purity, pressure, operating limits, complete electrical input, dimensions, weight, connection sizes, accessories and destination-market documentation.
Explore Gitan's PEM electrolyzers and completed equipment products for related sourcing options.
Request Technical Specifications and a Quotation
Contact Gitan about the PEM generator with 1000mL/min hydrogen output and 500mL/min oxygen output. Send your destination market, intended application and required quantity to discuss the appropriate configuration.
Need Custom Design and Development for CCM And PEM Electrolyzers?
We strongly support customer personalisation and customisation, providing the most suitable solutions based on different customer needs. If you have any customisation requirements, please contact us and we will provide you with the most professional advice and products.
View MoreRelated Products
We R&D, design, manufacturing and sales of PEM membrane electrodes, hydrogen and oxygen electrolytic cells and other ancillary products.