Provide customized design one-stop service

Gitan 1000ml/min hydrogen inhalation machine front view with H2 and O2 outlets
Dimensions of Gitan 1000ml/min hydrogen inhalation machine with silver vertical housing
Top control panel of Gitan hydrogen inhalation machine with timer and status indicators
Rear view of Gitan hydrogen inhalation machine showing ventilation openings and power connection
PEM electrolytic cell module for hydrogen generation equipment
Gitan 1000ml/min hydrogen inhalation machine front view with H2 and O2 outlets
Dimensions of Gitan 1000ml/min hydrogen inhalation machine with silver vertical housing
Top control panel of Gitan hydrogen inhalation machine with timer and status indicators
Rear view of Gitan hydrogen inhalation machine showing ventilation openings and power connection
PEM electrolytic cell module for hydrogen generation equipment

1000ml/min H2 Output PEM Hydrogen Inhalation Machine

Introduction

The Gitan 1000 mL/min PEM Hydrogen Inhalation Machine is a silver upright hydrogen-oxygen generation unit with a black curved top cover and an electronic control panel. The machine provides a rated hydrogen output of 1000 mL/min H₂ and an oxygen output of 500 mL/min O₂.

The front panel features one hydrogen outlet and one oxygen outlet, allowing the two gases to be connected separately. The unit also includes an integrated 2 L water tank and a top-mounted electronic operating interface.

The documented electrical configuration is AC 220 V / 50 Hz with a DC 15 V / 26 A constant-current power supply. The operating timer supports a range of 30–120 minutes. Feedwater must meet the specified TDS requirement of below 20 ppm.

Gitan welcomes enquiries from international distributors, equipment importers and OEM/ODM buyers. Contact us to discuss product specifications, order quantities and project requirements.


Description Specification Product Advantages
PEM water electrolysis technology diagram for Gitan 1000 mL/min hydrogen and 500 mL/min oxygen generator

Product Description

The Gitan 1000 mL/min Hydrogen Inhalation Machine is presented with Proton Exchange Membrane (PEM) water electrolysis technology for hydrogen and oxygen generation from purified water.

In PEM electrolysis, water reacts at the anode to produce oxygen, protons and electrons. The protons pass through the membrane to the cathode, where hydrogen gas is formed.

The machine has rated outputs of 1000 mL/min hydrogen (H₂) and 500 mL/min oxygen (O₂). One dedicated outlet is provided for each gas.

The illustration explains the basic PEM electrolysis principle. Internal component construction may differ from the conceptual diagram.


Technical Specifications

ParameterSpecification
Product Name1000 mL/min Hydrogen Inhalation Machine
Rated Hydrogen Output (H2)1000 mL/min
Rated Oxygen Output (O2)500 mL/min
Hydrogen Outlet1 dedicated H2 outlet
Oxygen Outlet1 dedicated O2 outlet
Water Tank Capacity2 L
AC Input220 V / 50 Hz
Constant-Current DC Supply15 V / 26 A
Feedwater TDS RequirementBelow 20 ppm
Recommended WaterPurified or distilled water
Operating Timer Range30–120 minutes
Control PanelTop-mounted electronic control panel
Exterior DesignSilver upright enclosure with black curved top cover
ManufacturerGitan (Guangdong) Electrode Industrial Co., Ltd.

Specifications refer to the documented product configuration. Please confirm final electrical and connection requirements with Gitan before ordering.


Product Advantages

Product Advantages

The Gitan 1000 mL/min PEM Hydrogen Inhalation Machine combines separate hydrogen and oxygen outputs, an integrated 2 L water tank, top-mounted electronic controls and a compact upright enclosure. The product is available for technical evaluation by equipment distributors, importers and OEM/ODM customers.

Rated Gas Outputs: Provides 1000 mL/min hydrogen and 500 mL/min oxygen.

Separate Gas Outlets: Features one dedicated hydrogen outlet and one oxygen outlet on the front panel.

2 L Water Tank: Includes an integrated water tank within the upright enclosure.

Electronic Control Panel: Top-mounted controls with a documented timer range of 30–120 minutes.

Constant-Current Power Supply: Documented DC 15 V / 26 A configuration with AC 220 V / 50 Hz input.

OEM/ODM Support: Gitan welcomes discussions on product sourcing, equipment configurations and project requirements.

Separate Hydrogen and Oxygen Outlets

The machine has two clearly identified gas connections on the front panel. The upper outlet is designated for hydrogen (H₂), while the lower outlet is designated for oxygen (O₂). Each gas is supplied through its corresponding connection.

Separate hydrogen and oxygen outlets on Gitan 1000 mL/min hydrogen inhalation machine showing H2 and O2 connections

Hydrogen Output (H₂): 1000 mL/min.

Oxygen Output (O₂): 500 mL/min.

Outlet Configuration: One hydrogen outlet and one oxygen outlet.

Gas connection sizes, pressure requirements and accessory compatibility should be confirmed with Gitan before equipment integration.

Water Quality Requirements

The machine incorporates an integrated 2 L water tank. The documented feedwater requirement is TDS below 20 ppm. Purified or distilled water should be used according to the manufacturer's operating instructions.

Water quality requirements for Gitan 1000 mL/min hydrogen generator with 2 L water tank and TDS below 20 ppm

Recommended Water: Purified or distilled water.

Feedwater TDS: Below 20 ppm.

Water Tank Capacity: 2 L.

Important: Do not use untreated tap water or mineral water that does not meet the specified requirements. Verify feedwater quality and follow the supplied operating and maintenance instructions.

Electronic Control and Timer

The Gitan hydrogen inhalation machine features a top-mounted electronic control panel for equipment operation. The documented timer range is 30–120 minutes, providing selectable operating durations within the specified range.

Operating Timer: 30–120 minutes.

AC Input: 220 V / 50 Hz.

DC Constant-Current Supply: 15 V / 26 A.

Customers should confirm the electrical requirements for their destination market and intended equipment configuration before ordering.

Factory Assembly and Testing

Gitan supplies hydrogen-generation equipment and related electrochemical components for international equipment distributors, importers and OEM/ODM buyers.

Customers can discuss product specifications, assembly requirements, functional verification procedures and project-specific inspection criteria with the Gitan team before placing an order.

Concept illustration of Gitan hydrogen inhalation machine assembly and functional testing

Frequently Asked Questions

What is the rated hydrogen output of this machine?

The machine has a rated hydrogen production capacity of 1000 mL/min (H₂).

How much oxygen does the machine produce?

The rated oxygen production capacity is 500 mL/min (O₂).

Are hydrogen and oxygen delivered through separate outlets?

Yes. The front panel includes one hydrogen outlet and one oxygen outlet.

What water quality is required?

The documented feedwater requirement is TDS below 20 ppm. Use purified or distilled water according to the equipment instructions.

What is the integrated water tank capacity?

The machine includes a 2 L water tank.

Does the machine have a timer?

Yes. The documented operating timer range is 30–120 minutes.

What electrical supply is required?

The documented configuration uses AC 220 V / 50 Hz input and a DC 15 V / 26 A constant-current supply.

Can customers discuss OEM/ODM configurations?

Yes. Gitan welcomes OEM/ODM enquiries. Customers can discuss product configuration, branding, quantities and integration requirements, subject to technical confirmation.

Contact Gitan for OEM/ODM Solutions

Looking for a 1000 mL/min hydrogen inhalation machine for equipment sourcing, distribution or an OEM project?

Contact Gitan to discuss hydrogen and oxygen output requirements, electrical configuration, gas connections, product specifications, customization options, pricing and delivery arrangements.

Contact Gitan for a Quotation

Need Custom Design and Development for CCM And PEM Electrolyzers?

We strongly support customer personalisation and customisation, providing the most suitable solutions based on different customer needs. If you have any customisation requirements, please contact us and we will provide you with the most professional advice and products.

View More

Related Products

We R&D, design, manufacturing and sales of PEM membrane electrodes, hydrogen and oxygen electrolytic cells and other ancillary products.

2000 mL/min PEM Hydrogen-Oxygen Generator | 1000 mL/min O₂ Output

Gitan PEM hydrogen-oxygen generator delivers 2000 mL/min H₂ and 1000 mL/min O₂. Separate outlets, 3 L tank, four casters, TDS ≤5 ppm.

2000 mL/min PEM Hydrogen-Oxygen Generator with 30 V DC Power

Gitan's 2000 mL/min PEM hydrogen-oxygen generator features a rated oxygen output of 1000 mL/min, separate H₂ and O₂ outlets, a 3 L water tank and four swivel casters. The electrical specifications are DC 30 V / 26 A and AC 220 V / 50 Hz. Purified or distilled water with TDS ≤5 ppm is required.

600–2000 mL/min Variable-Flow PEM Hydrogen-Oxygen Generator

Gitan's variable-flow PEM Hydrogen-Oxygen Generator features a published hydrogen output range of 600–2000 mL/min and a rated configuration of 2000 mL/min H₂ and 1000 mL/min O₂. It includes one hydrogen outlet, one oxygen outlet, a 3 L water tank and four swivel casters. Electrical specifications are DC 30 V / 26 A and AC 220 V / 50 Hz. Purif

1500 mL/min PEM Hydrogen Inhalation Machine

PEM hydrogen inhalation machine with 1500 mL/min H₂ and 750 mL/min O₂ rated output, a 3 L water tank, and separate hydrogen and oxygen outlets.

1500ml/min PEM Hydrogen-Oxygen Generator

Gitan 1500ml/min PEM hydrogen-oxygen generator with two hydrogen outlets, one oxygen outlet, touchscreen operation and integrated humidification.

PEM Hydrogen and Oxygen Generator – H2 1000mL/min, O2 500mL/min

The Gitan PEM Hydrogen and Oxygen Generator provides rated hydrogen output of 1000mL/min and oxygen output of 500mL/min through separate gas outlets. It uses PEM water electrolysis technology and features a 3L water tank. The specified DC electrical rating is 15V, 26A. Use purified or distilled water with TDS ≤ 5 ppm.