Provide customized design one-stop service
Introduction
The Gitan 1000 mL/min PEM Hydrogen Inhalation Machine is a silver upright hydrogen-oxygen generation unit with a black curved top cover and an electronic control panel. The machine provides a rated hydrogen output of 1000 mL/min H₂ and an oxygen output of 500 mL/min O₂.
The front panel features one hydrogen outlet and one oxygen outlet, allowing the two gases to be connected separately. The unit also includes an integrated 2 L water tank and a top-mounted electronic operating interface.
The documented electrical configuration is AC 220 V / 50 Hz with a DC 15 V / 26 A constant-current power supply. The operating timer supports a range of 30–120 minutes. Feedwater must meet the specified TDS requirement of below 20 ppm.
Gitan welcomes enquiries from international distributors, equipment importers and OEM/ODM buyers. Contact us to discuss product specifications, order quantities and project requirements.
Share:
Product Description
The Gitan 1000 mL/min Hydrogen Inhalation Machine is presented with Proton Exchange Membrane (PEM) water electrolysis technology for hydrogen and oxygen generation from purified water.
In PEM electrolysis, water reacts at the anode to produce oxygen, protons and electrons. The protons pass through the membrane to the cathode, where hydrogen gas is formed.
The machine has rated outputs of 1000 mL/min hydrogen (H₂) and 500 mL/min oxygen (O₂). One dedicated outlet is provided for each gas.
The illustration explains the basic PEM electrolysis principle. Internal component construction may differ from the conceptual diagram.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | 1000 mL/min Hydrogen Inhalation Machine |
| Rated Hydrogen Output (H2) | 1000 mL/min |
| Rated Oxygen Output (O2) | 500 mL/min |
| Hydrogen Outlet | 1 dedicated H2 outlet |
| Oxygen Outlet | 1 dedicated O2 outlet |
| Water Tank Capacity | 2 L |
| AC Input | 220 V / 50 Hz |
| Constant-Current DC Supply | 15 V / 26 A |
| Feedwater TDS Requirement | Below 20 ppm |
| Recommended Water | Purified or distilled water |
| Operating Timer Range | 30–120 minutes |
| Control Panel | Top-mounted electronic control panel |
| Exterior Design | Silver upright enclosure with black curved top cover |
| Manufacturer | Gitan (Guangdong) Electrode Industrial Co., Ltd. |
Specifications refer to the documented product configuration. Please confirm final electrical and connection requirements with Gitan before ordering.
Product Advantages
Product Advantages
The Gitan 1000 mL/min PEM Hydrogen Inhalation Machine combines separate hydrogen and oxygen outputs, an integrated 2 L water tank, top-mounted electronic controls and a compact upright enclosure. The product is available for technical evaluation by equipment distributors, importers and OEM/ODM customers.
Rated Gas Outputs: Provides 1000 mL/min hydrogen and 500 mL/min oxygen.
Separate Gas Outlets: Features one dedicated hydrogen outlet and one oxygen outlet on the front panel.
2 L Water Tank: Includes an integrated water tank within the upright enclosure.
Electronic Control Panel: Top-mounted controls with a documented timer range of 30–120 minutes.
Constant-Current Power Supply: Documented DC 15 V / 26 A configuration with AC 220 V / 50 Hz input.
OEM/ODM Support: Gitan welcomes discussions on product sourcing, equipment configurations and project requirements.
The machine has two clearly identified gas connections on the front panel. The upper outlet is designated for hydrogen (H₂), while the lower outlet is designated for oxygen (O₂). Each gas is supplied through its corresponding connection.

Hydrogen Output (H₂): 1000 mL/min.
Oxygen Output (O₂): 500 mL/min.
Outlet Configuration: One hydrogen outlet and one oxygen outlet.
Gas connection sizes, pressure requirements and accessory compatibility should be confirmed with Gitan before equipment integration.
The machine incorporates an integrated 2 L water tank. The documented feedwater requirement is TDS below 20 ppm. Purified or distilled water should be used according to the manufacturer's operating instructions.

Recommended Water: Purified or distilled water.
Feedwater TDS: Below 20 ppm.
Water Tank Capacity: 2 L.
Important: Do not use untreated tap water or mineral water that does not meet the specified requirements. Verify feedwater quality and follow the supplied operating and maintenance instructions.
The Gitan hydrogen inhalation machine features a top-mounted electronic control panel for equipment operation. The documented timer range is 30–120 minutes, providing selectable operating durations within the specified range.
Operating Timer: 30–120 minutes.
AC Input: 220 V / 50 Hz.
DC Constant-Current Supply: 15 V / 26 A.
Customers should confirm the electrical requirements for their destination market and intended equipment configuration before ordering.
Gitan supplies hydrogen-generation equipment and related electrochemical components for international equipment distributors, importers and OEM/ODM buyers.
Customers can discuss product specifications, assembly requirements, functional verification procedures and project-specific inspection criteria with the Gitan team before placing an order.

The machine has a rated hydrogen production capacity of 1000 mL/min (H₂).
The rated oxygen production capacity is 500 mL/min (O₂).
Yes. The front panel includes one hydrogen outlet and one oxygen outlet.
The documented feedwater requirement is TDS below 20 ppm. Use purified or distilled water according to the equipment instructions.
The machine includes a 2 L water tank.
Yes. The documented operating timer range is 30–120 minutes.
The documented configuration uses AC 220 V / 50 Hz input and a DC 15 V / 26 A constant-current supply.
Yes. Gitan welcomes OEM/ODM enquiries. Customers can discuss product configuration, branding, quantities and integration requirements, subject to technical confirmation.
Looking for a 1000 mL/min hydrogen inhalation machine for equipment sourcing, distribution or an OEM project?
Contact Gitan to discuss hydrogen and oxygen output requirements, electrical configuration, gas connections, product specifications, customization options, pricing and delivery arrangements.
Need Custom Design and Development for CCM And PEM Electrolyzers?
We strongly support customer personalisation and customisation, providing the most suitable solutions based on different customer needs. If you have any customisation requirements, please contact us and we will provide you with the most professional advice and products.
View MoreRelated Products
We R&D, design, manufacturing and sales of PEM membrane electrodes, hydrogen and oxygen electrolytic cells and other ancillary products.